top of page
Leasing a Home

Let us help you keep your family safe 

Did you know? 

The old ionisation smoke alarms can be slow to react, and may not give you or your loved ones enough time to escape.
That's why there's new legislation to install photoelectric smoke alarms, which have been proven to be more effective in the domestic home.


Upgrading your smoke alarms today could save a life.

Property Owners: About

Existing Properties - Your home

From 1 January 2017

  • Existing smoke alarms manufactured more than 10 years ago must be replaced with photoelectric smoke alarms which comply with Australian Standards (AS) 3786-2014. (Note: the date should be stamped on the back)

  • Smoke alarms that do not operate when tested must be replaced immediately.

  • Existing hardwired smoke alarms that need replacement, must be replaced with a hardwired photoelectric smoke alarm.

Property Owners: Text

From 1 January 2027

  • All existing private homes, townhouses and units will require photoelectric interconnected smoke alarms. These must be either a hardwired (eg. 240v) or non-removable 10 year battery powered type alarm.

  • The legislation requires smoke alarms must be installed in the following locations:

    • on each storey

    • in each bedroom

    • in hallways that connect bedrooms and the rest of the dwelling

    • if there is no hallway, between the bedroom and other parts of the storey; and

    • if there are no bedrooms on a storey, at least one smoke alarm must be installed in the most likely path of travel to exit the dwelling.

Property Owners: Text

For dwellings being sold, leased or an existing lease renewed

From 1 January 2017

  • Existing smoke alarms manufactured more than 10 years ago must be replaced with photoelectric smoke alarms which comply with Australian Standards (AS) 3786-2014. (Note: the date should be stamped on the back)

  • Smoke alarms that do not operate when tested must be replaced immediately.

  • Existing hardwired smoke alarms that need replacement, must be replaced with a hardwired photoelectric smoke alarm.

  • To get everyone out safely during a house fire, it is essential to also have a well-practised fire escape plan.

  • Existing landlord’s and tenant’s obligations continue. Property sellers must continue to lodge a Form 24 stating the requirements of the legislation have been met. See New Smoke Alarm Legislation for more details.

Property Owners: Text

From 1 January 2022

  • All homes or units being sold or leased, or existing leases renewed, will require hardwired photoelectric, interconnected smoke alarms. Non-removable 10-year battery smoke alarms can be installed in place

  • Smoke alarms in the dwelling must:

  • be photoelectric (AS3786-2014); and

  • not also contain an ionisation sensor; and

  • Be hardwired to the mains power supply, if currently hardwired. Otherwise, smoke alarms can be either hardwired or powered by a non removable 10 yr battery or a combination of both.

  • be interconnected with every other smoke alarm in the dwelling so all activate together.

  • The legislation requires smoke alarms must be installed in the following locations:

    • on each storey

    • in each bedroom

    • if there is no hallway, between the bedroom and other parts of the storey; and

    • if there are no bedrooms on a storey, at least one smoke alarm must be installed in the most likely path of travel to exit the dwelling.

Property Owners: Text
Property Owners: Inventory
bottom of page